Resistance and temperature · Question 47 of 60

Filament lamps usually burn out exactly when switched on. Why?

1 answer is correct. Hard Created with AI

Show answer

Answer

  • B The cold filament has a low resistance, so the current is briefly very large.

Explanation

When cold, tungsten has about a tenth of its operating resistance. In the first moment several times the normal current flows, and a thin spot in the filament melts.